| Getting Started | Documentation | Glish | Learn More | Programming | Contact Us |
| Version 1.9 Build 1488 |
|
Functions that have been implemented in the iramcalibrater tool are:
# Include the iramcalibrater functionality
include 'iramcalibrater.g'
# Create a iramcalibrater tool
myic:=iramcalibrater(msname='07feb97-g067.ms');
# Do a selection of the better data between the online radiometric
# corrected data and the non-corrected data
myic.phcor(trial=F);
# Perform the bandpass calibration
myic.rf(fieldname='0528+134', freqgrp='3mm-LSB', visnorm=F, bpnorm=T,
gibb= 2, drop=0);
# Perform the phase calibration
myic.phase(fieldnames=['0528+134', '0415+379'], freqgrp='3mm-LSB');
# Perform the flux calibration
myic.flux(fieldnames=['0528+134', '0415+379', 'MWC349'], freqgrp='3mm-LSB', plot=T);
# Perform the amplitude calibration
myic.amp(fieldnames=['0528+134', '0415+379'], freqgrp='3mm-LSB')
# Extract the calibrated target source and append it to another ms
myic.uvt(fieldname='GG_TAU', spwid=7, filename='ggtau3mm.ms', option='append');
The iramcalibrater tool needs to be constructed with an associated ms.
| iramcalibrater | Construct an iramcalibrater tool |
| amp | perform amplitude calibration on the data |
| done | Close the iramcalibrater tool |
| flux | perform flux calibration on the data |
| phase | perform phase calibration on the data |
| phcor | Select data atmospheric corrected data or not |
| rf | perform phase and amplitude bandpass calibration |
| uvt | to extract calibrated and combine it into another ms |